aobo

ABDT-K Coriolis Mass Flowmeter

The Coriolis mass flowmeter provides high-performance multi-parameter measurement for all industries and various fluids, capable of directly measuring mass flow


Characteristics

Accuracy:±0.1%
Nominal diameter range:DN5-DN350(½-14″)
Max nominal pressure:PN25
Medium temperature range:-240 to +350°C / -400 to +662°F
Measuring range:96-3266000kg/h

 

 

 

 

Overview

The ABDT-K coriolis series mass flowmeter uses the principle of Coriolis force. By measuring the Coriolis force acting on the fluid in the pipeline, it can directly measure the mass flow of the fluid. The Coriolis force is only related to the mass and velocity of the fluid. This principle eliminates the influence of changes in parameters such as temperature, pressure, fluid state, and density on measurement accuracy. It directly provides accurate flow and density values for various media under complex environmental conditions without the need for intermediate parameter conversions, avoiding measurement errors caused by such conversions, thus achieving high-precision and accurate measurement.

Features

  • Enables direct measurement of the mass flow rate of fluid in the pipeline without changing any parameters, avoiding some measurement errors from intermediate links. Its mass flow rate maintains high accuracy and good repeatability within a wider turndown ratio
  • The range of fluids that can be measured is extensive, including steady uniform flows of common viscosity fluids, high viscosity fluids, non-Newtonian fluids, slurries containing solid components, and liquids with trace amounts of gas
  • Due to low vibration, the measuring tube of the K flowmeter can be regarded as having no moving parts, which reduces maintenance, enhances stability, and extends the flowmeter’s lifespan
  • In addition to mass flow measurement, density, temperature, and even consistency can also be measured and output

Measuring principle

Coriolis

Measured media

Liquids, Gases

Nominal diameter range

DN5-DN350(½-14″)

Wetted materials

316L; HC alloy; More customizable

Measured variables

Mass flow, mass total

Volume flow, volume total

Temperature, density

Accuracy

±0.1%,±0.15%,±0.2%,±0.5%

Repeatability

±0.025%

Measuring range

96-3266000kg/h

Max nominal pressure

PN25

Medium temperature range

-240 to +350°C / -400 to +662°F

Ambient temperature range

-40 to +60°C/-40 to +140°F

Protection

Sensor IP66/IP67

Transmitter IP66/IP67

Display/Operation

4-line backlit display with touch control, Remote display available

Outputs

Pulse, 4-20mA

Communication

HART, RS485 Modbus

Power supply

AC220V

DC24V

Explosion-proof

SensorEx ib IIC T1-T6 Gb

Transmitter Ex d [ib] IIC T6 Gb

           

           

           

Products

Model No

Manual

Coriolis Mass Flow Meter-Brochure
ABDT-K

Contact Us

* The marked fields are mandatory

Need more information?